Ready-to-use CSI MasterFormat specification language for Section 04 72 00. Copy and paste directly into your project specifications. Three formats available for different spec-writing workflows.
SECTION 04 72 00 - ARCHITECTURAL CAST STONE
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes: Precast architectural cast stone coping and parapet caps.
B. Related Sections:
1. Section 04 20 00 - Unit Masonry
2. Section 07 92 00 - Joint Sealants
1.2 REFERENCES
A. ASTM C1364 - Standard Specification for Architectural Cast Stone.
B. ASTM C1194 - Standard Test Method for Compressive Strength of
Architectural Cast Stone and Precast Concrete.
C. ASTM C666 - Standard Test Method for Resistance of Concrete to
Rapid Freezing and Thawing.
D. ASTM C947 - Standard Test Method for Flexural Properties of
Thin-Section Glass-Fiber-Reinforced Concrete.
1.3 SUBMITTALS
A. Product Data: Manufacturer’s data sheets, mix designs, and test reports.
B. Samples: Two samples minimum, 6-inch minimum length, each finish color.
C. Shop Drawings: Layout, profiles, dimensions, anchoring details.
D. Test Reports: ASTM C666 freeze-thaw test results; compressive strength.
1.4 QUALITY ASSURANCE
A. Manufacturer: Minimum 10 years experience manufacturing architectural
cast stone per ASTM C1364.
B. Compressive Strength: Minimum 6,500 psi at 28 days.
C. Absorption: Maximum 6% per ASTM C642.
D. Freeze-Thaw: 300+ cycles per ASTM C666 with less than 0.10% mass loss.
PART 2 - PRODUCTS
2.1 CAST STONE COPING
A. Material: Architectural cast stone per ASTM C1364.
B. Mix Design: Portland cement, limestone aggregate, integral pigments,
mineral admixtures. No fly ash in exposed faces.
C. Profiles: As shown on drawings — [single-slope / double-slope / flat].
D. Drip Edge: [Integral / Applied]. Min 3/4-inch projection.
E. Color: [Portland Grey / Bucks County Buff / Old World Cream / Carbon Blend]
as selected by Architect. Color to be consistent throughout project.
F. Finish: Smooth-form, acid-washed, or sandblasted as specified.
G. Joints: 3/8-inch open joints with backer rod and sealant per Section 07 92 00.
2.2 GFRC COPING (Where Scheduled)
A. Material: Glass fiber reinforced concrete per ASTM C947 and PCI MNL-128.
B. Glass Fiber Content: Minimum 5% by weight, alkali-resistant.
C. Panel Thickness: Minimum 3/4-inch face mix; total minimum 3/4-inch.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Install per manufacturer’s written instructions and shop drawings.
B. Bearing surfaces: Level, clean, free of debris. Mortar bed or
setting compound as recommended by manufacturer.
C. Anchor cast stone per shop drawings using stainless steel anchors.
D. Control joints at maximum 20-foot intervals unless noted otherwise.
E. Slope coping min 1/8-inch per foot away from building.
3.2 TOLERANCES
A. Variation in cross-section: ±1/8 inch.
B. Variation in length: ±1/8 inch.
C. Variation from level: ±1/4 inch in 10 feet.
END OF SECTION 04 72 00
COLUMN_A,COLUMN_B,COLUMN_C,COLUMN_D
Section,04 72 00,Architectural Cast Stone: Coping & Parapet Caps,
CSI Format,MasterFormat 2024,,
Part,Topic,Requirement,Reference
1.1,Scope,Coping and parapet caps,
1.2,References,ASTM C1364 (Cast Stone),,
1.2,References,ASTM C1194 (Compressive Strength),,
1.2,References,ASTM C666 (Freeze-Thaw),,
1.2,References,ASTM C947 (GFRC Flexural),,
1.3,Submittals,Product data; Samples; Shop drawings; Test reports,,
1.4,QA,Fabricator 10+ years experience; Independent lab testing,ASTM C1364
1.4,QA,Compressive strength 6,500 psi minimum,,
1.4,QA,Freeze-thaw 300+ cycles <0.10% mass loss,ASTM C666
2.1,Cast Stone Coping,Material per ASTM C1364,,
2.1,Profiles,Single-slope / double-slope / flat,,
2.1,Drip Edge,Integral or applied; min 3/4-inch projection,,
2.1,Finishes,Portland Grey / Bucks County Buff / Old World Cream / Carbon Blend,,
2.2,GFRC Coping,Per ASTM C947 and PCI MNL-128,,
2.2,Glass Fiber,5% minimum by weight,,
Mark,Profile,Width,Length,Finish,Drip Edge,Qty,Location
CP-1,Single-slope,12",24",Portland Grey,Integral,[qty],Parapet — N elevation
CP-2,Double-slope,16",24",Bucks County Buff,Applied,[qty],Parapet — E/W elevation
CP-C,Corner unit,12"×12",—,Portland Grey,Integral,[qty],All corners
[ Additional rows for each coping type — edit to match project ]
END OF SECTION,,,
COPING AND PARAPET CAPS — CAST STONE SPECIFICATION
MATERIAL: Architectural cast stone per ASTM C1364
STANDARD: ASTM C666 freeze-thaw resistance; ASTM C947 (GFRC where scheduled)
CSI SECTION: 04 72 00
PHYSICAL REQUIREMENTS:
- Compressive Strength: 6,500 psi minimum at 28 days
- Water Absorption: 6% maximum (ASTM C642)
- Freeze-Thaw: 300+ cycles, <0.10% mass loss (ASTM C666)
- Density: 130–145 pcf
PROFILES AVAILABLE:
- Single-slope (recommended: 1/8" per foot minimum)
- Double-slope
- Flat / level top
- Bullnose (pool deck applications)
- Custom profiles per shop drawings
STANDARD FINISHES:
- Portland Grey (PG-01) — cool neutral
- Bucks County Buff (BC-02) — warm limestone
- Old World Cream (OW-03) — light antiqued
- Carbon Blend (CB-04) — deep charcoal
- Custom matching available on request
INSTALLATION NOTES:
- Slope min 1/8" per foot away from building
- Stainless steel anchors required
- Control joints max 20 ft on center
- Sealant: paintable polyurethane or silicone, color match
MANUFACTURER: Mesa Precast
Contact: Jess Mason, 480-600-6776
archstoneglobal.polsia.app/specs-coping-parapet-caps