DIVISION 04 — MASONRY
SECTION 04 72 00 — ARCHITECTURAL CAST STONE (FIREPLACE SURROUNDS & MANTELS)
PART 1 — GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. This Section includes:
1. Cast stone fireplace surrounds including legs (jambs), fascia, mantel shelf, and frieze panels
2. Cast stone overmantel panels and decorative elements
3. Cast stone hearth pads and raised hearth components
4. Cast stone outdoor fireplace surrounds and cap elements
5. GFRC fire surround panels per Section 03 49 00 (where noted on drawings)
B. Related Sections:
1. Section 03 49 00 — Glass Fiber Reinforced Concrete (GFRC surround panels)
2. Section 04 20 00 — Unit Masonry (firebox masonry substrate)
3. Section 07 92 00 — Joint Sealants (perimeter caulk at surround-to-wall joints)
4. Section 09 29 00 — Gypsum Board (drywall return at surround legs)
1.3 REFERENCES
A. ASTM C1364 — Standard Specification for Architectural Cast Stone
B. ASTM C1194 — Standard Test Method for Compressive Strength of Architectural Cast Stone and Precast Concrete
C. ASTM C150 — Standard Specification for Portland Cement
D. ASTM C33 — Standard Specification for Concrete Aggregates
E. ASTM C666 — Standard Test Method for Resistance of Concrete to Rapid Freezing and Thawing
F. ASTM E119 — Standard Test Methods for Fire Tests of Building Construction
G. ASTM E136 — Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 Degrees C
H. CSI MasterFormat 04 72 00 — Cast Stone Masonry
1.4 SUBMITTALS
A. Product Data: Manufacturer's technical data sheets, standard profiles, and available finish samples.
B. Shop Drawings: Full-size or scaled surround elevation with all components labeled, section profiles through jambs and mantel shelf, joint locations, and anchorage details.
C. Samples: Submit minimum 6" x 6" sample of each specified finish and color. Color shall be approved by architect before production.
D. Test Reports: Provide third-party laboratory test data confirming ASTM C1364 compliance: compressive strength (min. 6,500 psi at 28 days) and water absorption (max. 6% by weight).
E. Quality Assurance Documentation: Manufacturer experience record, plant quality program, and ASTM C1364 compliance statement.
1.5 QUALITY ASSURANCE
A. Manufacturer: Minimum 10 years' experience in architectural cast stone production. Dedicated architectural cast stone facility capable of producing complex profiles, moldings, and carved ornamental elements.
B. Testing: Independent laboratory testing per ASTM C1364. Minimum compressive strength 6,500 psi at 28 days. Maximum water absorption 6% by weight.
C. Samples and Mock-ups: Provide surround component samples per submittal schedule. Mock-up surround installation per architect's direction if required by Contract Documents.
D. Pre-installation Conference: Coordinate with general contractor, mason, and fireplace installer before cast stone delivery.
1.6 DELIVERY, STORAGE & HANDLING
A. Delivery: Deliver components on padded pallets or custom shipping frames. Label each piece with shop drawing mark.
B. Storage: Store horizontally on padded supports. Protect exposed finished surfaces from dirt, staining, and impact damage. Do not store directly on ground.
C. Handling: Lift pieces with padded slings or by design pick points. Do not drag pieces across each other.
PART 2 — PRODUCTS
2.1 MANUFACTURERS
A. Acceptable Manufacturer: Mesa Precast, Mesa, AZ — Contact: Jess Mason, 480-600-6776
1. Additional manufacturing locations: Texas, Pennsylvania
2. Representative: contact via archstoneglobal.polsia.app
B. Substitutions: Equal products by other ASTM C1364 certified manufacturers may be submitted 10 days prior to bid with test data, project references of comparable scope, and finish samples.
2.2 MATERIALS — CAST STONE
A. Portland Cement: ASTM C150, Type I or Type II.
B. Aggregates: ASTM C33, washed and graded. Aggregate size and color selected to achieve specified finish.
C. Water: Potable.
D. Coloring: Inorganic iron oxide pigments, UV-stable, compatible with Portland cement. Uniformly dispersed through full cross-section of unit.
E. Mix Design: Designed to achieve minimum 6,500 psi compressive strength at 28 days and maximum 6% water absorption per ASTM C1364.
2.3 PHYSICAL PROPERTIES (ASTM C1364)
A. Compressive Strength: 6,500 psi minimum at 28 days.
B. Water Absorption: 6% maximum by weight.
C. Freeze-Thaw (ASTM C666): 300 cycles minimum, no visible deterioration, no greater than 0.1% linear expansion.
D. Modulus of Rupture: 1,200 psi minimum.
2.4 COMPONENTS — FIREPLACE SURROUND SYSTEM
A. Surround Legs (Jambs): Vertical side members framing the firebox opening. Profile per drawings. Standard height 42–54" to mantel shelf underside. Custom heights available.
B. Fascia / Frieze Panel: Horizontal member spanning between legs above firebox opening. Molding profile as specified. Width per drawings.
C. Mantel Shelf: Projecting horizontal shelf supported by legs and/or corbels. Standard projection 4–8" from fascia face; custom projections to 18" available. Shelf thickness minimum 2".
D. Corbels and Brackets: Cast integral support elements at mantel shelf bearing. Profiles include plain, scrolled, acanthus, and dentil per drawings.
E. Overmantel Panels: Decorative panels above mantel shelf. Classical and contemporary profiles. Optional mirror or artwork recess framing.
F. Hearth Pad: Flush or raised hearth platform at firebox base. Thickness minimum 2". Custom sizes to accommodate firebox opening dimension.
G. Keystone and Accent Details: Decorative keystones, corbels, and carved ornamental elements as shown on drawings.
2.5 DIMENSIONS AND TOLERANCES
A. Dimensional tolerances per ASTM C1364:
1. Length/width: +/- 1/8" on pieces under 24"; +/- 3/16" on pieces 24"–72"
2. Thickness: +/- 1/8" from specified dimension
3. Squareness (diagonal): 1/8" maximum on pieces under 24"; 3/16" on larger
B. Profile tolerances: +/- 1/16" on molding profiles. Miter joints shall fit tight with maximum 1/16" gap.
2.6 FINISHES
A. Standard Finishes: Portland (warm gray), Bucks County (buff/tan), Old World (antique cream), Carbon (charcoal gray).
B. Texture Options: Smooth (form finish), light sandblast, medium sandblast, acid-etch, and custom tooled profiles.
C. Custom Colors: Match architect's physical sample or specified color reference. Submit color batch samples before full production.
PART 3 — EXECUTION
3.1 EXAMINATION
A. Verify firebox opening dimensions, substrate plumb and level, and rough opening width/height match shop drawings before installation.
B. Confirm that firebox and hearth substrate framing can carry the weight of cast stone components (typically 80–400 lbs total depending on surround size).
C. Do not begin installation if conditions are unsatisfactory.
3.2 INSTALLATION
A. Install cast stone surround components per approved shop drawings and manufacturer's written instructions.
B. Setting Bed: Set components in Type S mortar (ASTM C270) or approved flexible adhesive mortar. Do not install components in hard Portland cement mortar without architect review.
C. Joints: 1/4" nominal joint width between components. Fill joints with matching sanded grout or approved joint compound after setting mortar has cured.
D. Mantel Shelf: Secure mantel shelf with masonry anchors or adhesive anchors per engineer's recommendation for shelf weight and projection. Stainless steel anchors for exterior and high-humidity applications.
E. Hearth Pad: Install level on appropriate substrate. Minimum 1" mortar bed on concrete subfloor. Grout perimeter joint to match finish.
F. Perimeter Caulk: Apply color-matched paintable caulk at cast stone-to-drywall or cast stone-to-tile joints. Do not use hard mortar at dissimilar material joints.
3.3 TOLERANCES (INSTALLED)
A. Plumb of legs: +/- 1/8" per 4 ft of height
B. Level of mantel shelf: +/- 1/8" over full shelf length
C. Joint width: +/- 1/16" from specified joint width
3.4 CLEANING & PROTECTION
A. Protection: Cover completed surround with cardboard or polyethylene during finish work. Remove tape and adhesive protectors before paint or finish work begins.
B. Cleaning: Clean exposed surfaces with water and pH-neutral detergent. Remove mortar drips with wooden or plastic scraper — do not use steel tools on finished face. Do not use acid cleaners on cast stone.
C. Sealing: Apply penetrating silicone or silane/siloxane sealer to outdoor surrounds per manufacturer's recommendation. Interior surrounds do not require sealing.
END OF SECTION 04 72 00
COLUMN_A,COLUMN_B,COLUMN_C,COLUMN_D
Section,04 72 00,Architectural Cast Stone — Fireplace Surrounds & Mantels,
CSI Format,MasterFormat 2024,,
Part,Topic,Requirement,Reference
1.1,Related Docs,Drawings and General Conditions apply,Div 01
1.2,Scope,"Cast stone surround legs, fascia, mantel shelf, corbels, hearth pads, overmantel panels",,
1.3,References,ASTM C1364 (Cast Stone),,
1.3,References,ASTM C1194 (Compressive Strength),,
1.3,References,ASTM C150 (Portland Cement),,
1.3,References,ASTM C33 (Aggregates),,
1.3,References,ASTM C666 (Freeze-Thaw),,
1.3,References,ASTM E136 (Non-Combustibility),,
1.4,Submittals,Product data; Shop drawings with all components labeled; Finish samples; Test reports,,
1.5,QA,Manufacturer 10+ years cast stone experience; Independent lab testing,ASTM C1364
1.6,Handling,Padded pallets; Labeled pieces; No ground storage,,
2.1,Manufacturer,Mesa Precast (AZ/TX/PA),480-600-6776 — Jess Mason
2.2,Cement,ASTM C150 Type I or II Portland,,
2.2,Aggregates,ASTM C33 washed and graded,,
2.2,Coloring,Inorganic iron oxide pigments; UV-stable; Full cross-section color,,
2.3,Comp. Str.,6500 psi minimum at 28 days,ASTM C1364
2.3,Absorption,6% maximum by weight,ASTM C1364
2.3,Freeze-Thaw,300 cycles; no visible deterioration,ASTM C666
2.3,MOR,1200 psi minimum,,
2.4,Surround Legs,42-54" standard height; Custom heights available,,
2.4,Mantel Shelf,4-8" standard projection; up to 18" custom; 2" min thickness,,
2.4,Hearth Pad,Flush or raised; 2" minimum thickness,,
2.5,Tolerances,"Length/width +/-1/8" to 3/16"; Thickness +/-1/8",ASTM C1364
2.6,Finishes,Portland / Bucks County / Old World / Carbon,Custom available
3.2,Setting,Type S mortar (ASTM C270); 1/4" nominal joints,,
3.2,Anchors,Masonry or adhesive anchors for mantel shelf; SS for exterior,,
3.3,Tolerances,Legs plumb +/-1/8"/4ft; Shelf level +/-1/8",,
3.4,Cleaning,pH-neutral detergent; No acid cleaners; No steel tools on face,,
3.4,Sealing,Penetrating silane/siloxane sealer for exterior surrounds,,
END OF SECTION,,,
04 72 00 - ARCHITECTURAL CAST STONE (FIREPLACE SURROUNDS & MANTELS)
SCOPE: Furnish and install cast stone fireplace surround system including legs, fascia, mantel shelf, corbels, overmantel panels, and hearth pad per these specifications and reviewed shop drawings.
MATERIAL: Architectural cast stone per ASTM C1364:
- Portland cement: ASTM C150, Type I or II
- Aggregates: ASTM C33, washed and graded
- Coloring: Inorganic iron oxide pigments, UV-stable, full cross-section
- Compressive strength: 6,500 psi minimum at 28 days
- Water absorption: 6% maximum by weight
- Freeze-thaw: 300 cycles, no visible deterioration (ASTM C666)
- Non-combustible: ASTM E136 classification
MANUFACTURER: Mesa Precast | ArchStone Global
- Mesa, AZ — Contact: Jess Mason, 480-600-6776
- Additional plants: Texas, Pennsylvania
COMPONENTS: Surround legs (jambs) 42-54" standard height; Fascia/frieze panel; Mantel shelf 4-8" standard projection (up to 18" custom), 2" min. thickness; Corbels and brackets per profile drawings; Overmantel panels; Hearth pad minimum 2" thick.
TOLERANCES: Length/width +/- 1/8" (under 24") or +/- 3/16" (24"-72"). Thickness +/- 1/8". Installed plumb +/- 1/8" per 4 ft. Mantel shelf level +/- 1/8" over full length.
FINISHES: Standard colors (Portland, Bucks County, Old World, Carbon). Textures: smooth, sandblast, acid-etch. Custom color matching available.
INSTALLATION: Type S mortar setting bed (ASTM C270). 1/4" nominal joints, sanded grout after cure. Masonry or adhesive anchors for mantel shelf. Stainless steel anchors for exterior. Color-matched caulk at dissimilar material joints. No hard mortar at perimeter.
CLEANING: pH-neutral detergent and water. No acid cleaners. No steel tools on finished face. Penetrating sealer for exterior surrounds.